INSTALLING
YOUR
DOUBLE-WALL
CHIMNEY
SYSTEM
BEFORE
YOU
BEGIN INSTALLING
YOUR
DOUBLE
FIRESTOP
SPACERS
WALL
CHIMNEY
SYSTEM
DETERMINE
HOW
MUCH
PtPE
AND
ACCESSORIES
YOU
WILL
NEED.
SEE
firestop spacers are required
at
each point
where
the
PAGE
6
FOR
EXAMPLES
Of
CHIMNEY AND
TERMI-
chimney penetrates
a
floor
or
ceiling
joist
space.
Their
NATION
DESIGNS.
purpose
is
twofold:
they
eslablish
and
maintain
the
required
clearance betwekn
the
chimney
and combus-
tible
materials,
and
they provide complete separation
from
one
floor
space
to
another
floor or attic space,
as
Each
double-wall chimney section
consists
of
an
outer
required
by
most
codes.
When
penetrating
a
floor
or
pipe, flue pipe and single-piece
wire
spacer. The pipe
ceiling
at
an angle, either the
15'
or
30'
firestop
must
be
sections
are
not
unitized
and
must
be
assembled
inde-
used.
(See
Figure
22).
pendently
as
the
chimney
is
installed. (Figure
21).
FIGURE
21
INNER
PIPE
+zsZ(
RESTOP
SPACER
If pipe passes
through
a
framed opening
between
floors,
install
a
firestop spacer
to
the
bottom
of
the
joists
(Figure
22).
When pipe passes
into
the
attic
space,
install the firestop
spacer
on the
top
of
the
joists (Figure
23)
and
secure with sheet
metal
screws
or
nails.